![]() |
Kaizer Contreras Limited Term Appointment - Pro Staff kcontreras@apl.washington.edu |
Videos
![]() |
Ultrasonic Kidney Stone Treatment for Pet Cats and Marine Mammals A research kidney stone treatment system that is now undergoing clinical trials in humans was modified to noninvasively fragment stones in pet cats. The design accounted for differences in anatomic scale, acoustic window, skin-to-stone depth, and stone size. Veterinarian collaborators at the University of Minnesota have treated ureteral stones successfully in three cats. |
20 Dec 2023
|
![]() |
Publications |
2000-present and while at APL-UW |
![]() |
xDDx: A numerical toolbox for ultrasound transducer characterization and design with acoustic holography Rosnitskiy, P.B., O.A. Sapozhnikov, V.A. Khokhlova, W. Kreider, S.A. Tsysar, G.P.L. Thomas, K. Contreras, and T.D. Khokhlova, "xDDx: A numerical toolbox for ultrasound transducer characterization and design with acoustic holography," IEEE Trans. Ultrason. Ferroelectr. Freq. Control, 72, 564-580, doi:10.1109/TUFFC.2025.3542405, 2025. |
More Info |
1 May 2025 ![]() |
![]() |
|||||
Transient acoustic holography is a useful technique for characterization of ultrasound transducers. It involves hydrophone measurements of the 2-D distribution of acoustic pressure waveforms in a transverse plane in front of the transducer—a hologram—and subsequent numerical forward projection (FP) or backward projection of the ultrasound field. This approach enables full spatiotemporal reconstruction of the acoustic field, including the vibrational velocity at the transducer surface. This allows identification of transducer defects as well as structural details of the radiated acoustic field such as sidelobes and hot spots. However, numerical projections may be time-consuming ( 1010 1011 operations with complex exponents). Moreover, backprojection from the measurement plane to the transducer surface is sensitive to misalignment between the axes of the positioning system and the axes associated with the transducer. This article presents an open-access transducer characterization toolbox for use in MATLAB or Octave on Windows computers (https://github.com/pavrosni/xDDx/releases). The core algorithm is based on the Rayleigh integral implemented in C++ executables for graphics and central processing units (GPUs and CPUs). The toolbox includes an automated procedure for correcting axes misalignments to optimize the visualization of transducer surface vibrations. Beyond using measured holograms, the toolbox can also simulate the fields radiated by user-defined transducers. Measurements from two focused 1.25-MHz 12-element sector transducers (apertures of 87 mm and focal distances of 65 and 87 mm) were used with the toolbox for demonstration purposes. Simulation speed tests for different computational devices showed a range of 0.2 s 3 min for GPUs and 1.6 s 57 min for CPUs. |
![]() |
Development of a contrast-enhanced ultrasound-guided high-intensity focused ultrasound system for coagulation of liver parenchyma Tam, A., and 11 others including K. Contreras, "Development of a contrast-enhanced ultrasound-guided high-intensity focused ultrasound system for coagulation of liver parenchyma," J. Trauma Acute Care Surg., 98, 662-666, doi:10.1097/TA.0000000000004397, 2025. |
More Info |
1 Apr 2025 ![]() |
![]() |
|||||
BACKGROUND |
![]() |
Histotripsy-induced bactericidal activity correlates to size of cavitation cloud in vitro Ambekar, P.A., Y.-N. Wang, T.D. Khokhlova, G.P.L. Thomas, P.B. Rosnitskiy, K. Contreras, D.F. Leotta, A.D. Maxwell, M. Bruce, S. Pierson, S. Totten, Y.N. Kumar, J. Thiel, K.T. Chan, W.C. Liles, E.P. Dellinger, A. Adedipe, W.L. Monsky, and T.J. Matula, "Histotripsy-induced bactericidal activity correlates to size of cavitation cloud in vitro," IEEE Trans. Ultrason. Ferroelectr. Freq. Control, 71, 1868-1878, doi:10.1109/TUFFC.2024.3476438, 2024. |
More Info |
9 Oct 2024 ![]() |
![]() |
|||||
Large abscesses are walled-off collections of pus and bacteria that often do not respond to antibiotic therapy. Standard of care involves percutaneous placement of indwelling catheter(s) for drainage, a long and uncomfortable process with high rehospitalization rates. The long-term goal of this work is to develop therapeutic ultrasound approaches to eradicate bacteria within abscesses as a noninvasive therapeutic alternative. Inertial cavitation induced by short pulses of focused ultrasound (histotripsy) is known to generate lethal mechanical damage in bacteria. Prior studies with Escherichia coli (E. coli) in suspension demonstrated that bactericidal effects increase with increasing peak negative amplitude, treatment time, and duty cycle. The current study investigated correlates of bactericidal activity with histotripsy cavitation cloud size. Histotripsy was applied to E. coli suspensions in 10-mL sample vials at 810 kHz, 1.2 MHz, or 3.25 MHz for 40 min. The cavitation activity in the sample vials was separately observed with high-speed photography. The cavitation cloud area was quantified from those images. A linear relationship was observed between bacterial inactivation and cavitation cloud size ( R2 = 0.98 ), regardless of the acoustic parameters (specifically frequency, pulse duration, and power) used to produce the cloud. |